Loading...
CyberPower PDU44004 Single Phase 240 - 200 VAC 15A Switched ATS PDU
Product #:
SYNX6505225
+1View All
Sold Out
This product is sold out and we do not know when we will be getting another shipment. We apologize for any inconvenience this may cause.
Check similar items above to see if a replacement product is available.
Product Description
CyberPower PDU44004 Single Phase 240 - 200 VAC 15A Switched ATS PDU
12 Outlets, 10 ft, 2 x IEC-320 C14, Horizontal, 1U, SNMP, LCD, 3YR Warranty
Ensure continued operation of critical devices with the CyberPower PDU44004 Switched ATS PDU. Ideal for data centers and network closets, this unit provides power redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable. Additionally, this unit offers real time remote and local monitoring and outlet management.
The PDU44004 supports inputs between 200-240V and includes (12) IEC C13 outlets. Dual IEC C14 power cords are plugged into separate power sources (A and B), and information about each power source is clearly displayed on the front panel LED indicator lights. Other features include an LCD with selectable background color, built-in web interface, and power event notifications. The CyberPower PDU44004 is protected by a three-year limited warranty.
The PDU44004 supports inputs between 200-240V and includes (12) IEC C13 outlets. Dual IEC C14 power cords are plugged into separate power sources (A and B), and information about each power source is clearly displayed on the front panel LED indicator lights. Other features include an LCD with selectable background color, built-in web interface, and power event notifications. The CyberPower PDU44004 is protected by a three-year limited warranty.
- Automated notifications: Email, SMS Text, and SNMP Trap
- Phase: Single
- Amps: 15A (Derated to 12A)
- Volts: 200-240V
- Frequency: 50/60Hz
- Plug type: 2 x IEC-320 C14
- Outlets: 12 x IEC-320 C13
- Size: 1U Rackmount
- Warranty: 3 year
- With a built-in digital current meter avoid potential overloads via switched PDUs
- IEC 60320 C13 receptacle type to ensure maximum productivity with added feasibility
- Modular design for better usability and increased efficiency
- Single Phase phase PDU provides optimal power output with added usability
- IEC 60320 C14 plug/connector type for efficient connectivity and feasible power output
- 230 V AC input voltage for maximum feasibility and added productivity
- 230 V AC output voltage for optimal performance with maximum feasibility
Product Specifications
-
Additional InformationInput Frequency Range : 50 Hz - 60 Hz Nominal Input Voltage : 240 - 200 VAC Phase : Single Phase Nominal Output Voltage : 240 - 200 VAC Outlet Banks : 1 Outlets - Total : 12 Overload Protection : None Power Source Transfer Time : 2-7 ms Source Failure Detection Time : 2-3 ms Total Transfer Time : <10 ms Environmental Sensor : Optional, via RJ45 Hardware Connection Port : Ethernet (RJ45) LCD : Multifunction LCD LED Indicators : Source Status Modular Expandability (Cascading) : Yes, via RJ45 Outlet switching : Yes Upgradeable firmware : Yes Cord Retention Tray/Cord Organizers : Yes External Site Ground Pin : Yes Material of Construction : Metal Operating Elevation : 0 - 13123 ft (0 - 4000 m) Operating Relative Humidity : 0 - 95 % (non-condensing) Operating Temperature : 32 - 113 °F (0 - 45 °C) Storage Elevation : 0 - 49213 ft (0 - 14999 m) Storage Temperature : 5 - 131 °F (-15 - 55 °C) Safety : UL62368 : FCC Class A : cTUVus/CE/UKCA
-
Brand NameCyberPower
-
Country of OriginChina
-
Depth8.5"
-
Environmental ComplianceRestriction of Hazardous Substances (RoHS)
-
Environmentally FriendlyYes
-
Height1.8"
-
Input Current15 A
-
Input Voltage230 V AC
-
Input Voltage Range200 V AC - 240 V AC
-
Limited Warranty3 Year
-
ManagementIPv4 TCP/IP UDP SNMPv1 HTTP NTP DNS Telnet DHCP SMTP FTP IPv6 SNMPv3 HTTPs SSH SSL TLS LDAP(S) RADIUS Syslog CLI Windows AD
-
Manufacturer Part NumberPDU44004
-
Mount TypeRack-mountable
-
Mounting OrientationHorizontal
-
Network (RJ-45)Yes
-
Output Voltage230 V AC
-
Output Voltage Range200 V AC - 240 V AC
-
PhaseSingle Phase
-
Plug/Connector Detail2 x IEC 60320 C14
-
Plug/Connector TypeIEC 60320 C14
-
Product ColorBlack
-
Product ModelPDU44004
-
Product NameSwitched ATS PDU PDU44004 12-Outlets PDU
-
Product SeriesSwitched ATS PDU
-
Product TypePDU
-
Rack Height1U
-
Receptacle Detail12 x IEC 60320 C13
-
Receptacle TypeIEC 60320 C13
-
Remote Outlet SwitchingYes
-
Width17.1"