APC NetShelter Rack PDU, Metered, 0U, 17.3kW 208V 3 Phase 60A, 30 C13 outlets

|
Product #: SYNX3343249
Image 1
View thumbnail 1
View thumbnail 2
View thumbnail 3
View thumbnail 4
Image 1
Pinch to zoom Pinch to zoom
View thumbnail 1
View thumbnail 2
View thumbnail 3
View thumbnail 4
$3,038.46
Loading...
Ships Free - This items ships free with your order
Delivered by Tue 5/20 Wed 5/21 - This is an estimated delivery timeline
Non-returnable - This is a non-returnable item
Loading...

Product Description

APC NetShelter Rack PDU, Metered, 0U, 17.3kW 208V 3 Phase 60A, 30 C13 outlets
Metered - IEC 60309 60A 3P+PE - 30 x IEC 60320 C13 - 208 V - 17.20 kW - Overload Protection - 6 ft Cord Length - 0U - Vertical - Rack-mountable - Tower
The APC Metered Rack PDU distributes reliable power within a rack through a single input and multiple output receptacles The AP8867 offers real-time remote monitoring of connected loads and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment The 0U PDU includes a IEC 60309 60A 3P + PE input plug with 1 83m (6ft) cord and (30) IEC 60320 C13 output receptacles The PDU can operate in a maximum ambient air temperature of up to 60°C (140°F) at full load The Network Management Card provides enhanced cybersecurity with secured interfaces and modified password policy The rack PDU integrates with EcoStruxureTM IT through a Network Management Card and can be accessed and configured via Web, SNMP, and Command Line Interface User-interactive LCD interface details current, real power, voltage, and energy measurements for local user access Embedded log memory with historical reporting enables users to meter power usage, optimize energy usage, and plan for capacity The PDU's locking IEC outlets, when used with locking power cords reduce the probability of accidentally disconnecting cords and dropping loads The rack PDU supports daisy-chaining of up to 4 PDUs on a single IP address An environmental monitoring port is available for external temperature/humidity monitoring (sensor sold separately, model AP9335T or AP9335TH) The rack PDU comes with a standard two-year warranty
More from the Manufacturer
  • Ideal for colocation, large data centers or distributed IT sites
  • Plan capacity and balance loads with +/- 3% metering accuracy (amps, volts, kW, kWh)
  • Real-time remote monitoring of connected load through EcoStruxureTM IT and other platforms
  • Stay on top by defining alarm thresholds in order to avoid overloaded circuits
  • Zero U toolless installation
  • Meters power to enable optimal energy and protect circuits
  • Fitted with multiple outlets for distribution of electrical power
  • LCD to monitor current, power and voltage measurements
  • Uses 6' long power cord to easily power
  • Meets Green Premium label to deliver compliance with the latest regulations, transparency on environmental impacts and low carbon dioxide emissions

Product Specifications

  • Additional Information
    Input Connections: IEC 309 60A 3P+PE
  • Additional Warranty Information
    2 years repair or replace
  • Brand Name
    APC by Schneider Electric
  • Certifications & Standards
    cUL Listed|UL Listed|VCCI Class A
  • Cord Length
    6 ft
  • Depth
    2"
  • EU RoHS Declaration URL
    https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=323194462&lang=en-us
  • End of Life Manual Availability
    https://download.schneider-electric.com/files?p_enDocType=Circularity+Profile&p_Doc_Ref=ENVEOLI1712014_EN
  • Environmental Compliance
    Restriction of Hazardous Substances (RoHS)
  • Environmental Profile Availability
    https://download.schneider-electric.com/files?p_enDocType=Environmental+Disclosure&p_Doc_Ref=ENVPEP1712014_EN
  • Environmentally Friendly
    Yes
  • For Country/Region
    United States
  • Form Factor
    Tower
  • Height
    72"
  • Input Voltage
    208 V
  • Lead Free
    Yes
  • Limited Warranty
    2 Year
  • Management
    SNMP Telnet Protocols: Web
  • Manufacturer Part Number
    AP8867
  • Mercury Free
    Yes
  • Mount Type
    Rack-mountable
  • Mounting Preference
    No Preference
  • Optimized Energy Efficiency
    Yes
  • Output Voltage
    208 V AC
  • Package Contents
    Rack PDU 2G, Metered, ZeroU, 17.2kW, 208V, (30) C13 Installation Guide Rack Mounting Brackets Safety Guide Serial Configuration Cable
  • Placement
    Side
  • Plug/Connector Type
    IEC 60309 60A 3P+PE
  • Power Rating (VA)
    17.20 kVA
  • Product Color
    Black
  • Product Line
    Metered Rack
  • Product Name
    Rack PDU 2G, Metered, ZeroU, 17.2kW, 208V, (30) C13
  • Product Take Back Program
    Yes
  • Product Type
    PDU
  • Protection Type
    Overload Protection
  • REACH Declaration URL
    https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfReach&pid=323194462&lang=en-us
  • REACH free of SVHC
    Yes
  • Rack Height
    0U
  • Receptacle Detail
    30 x IEC 60320 C13
  • Receptacle Type
    IEC 60320 C13
  • RoHS Exemption Information
    https://download.schneider-electric.com/files?p_enDocType=Declaration+of+Conformity+%28Sustainability%29&p_Doc_Ref=AP8867_ROHS_DECLARATION&p_FileName=AP8867KIT_ROHS_DECLARATION_US.pdf
  • Width
    2.2"